Look Carbon Monoxide Detector
Carbon Monoxide Detector Probe Electrochemistry. high Base. Sensitivity 0-300ppm. Operating temperature: -10At 50 ° C. cabling: 2×1,5mm. feeding: 10 a 15 Vdc. Consumption: 5,5mA / 12V (10,8mA with LED). Dimensions 100(D) x 60(A)mm. useful life: 7 years.
Related Products

Carbon Monoxide Central COFEM
carbon monoxide detection Center 1 area with double ventilation and exit to batteries. Up until 22 detectors per zone. Complies with standard UNE23300.

Look Carbon Monoxide Central
Central detection Carbon monoxide 5 areas.
Maximum 16 detectors per zone.
installation by 2 wire free architecture and no polarity.
3 programmable levels: ventilation, turbo ventilation and alarm (from 10 in 10 ppm) with independent relay outputs.
Time between readings of a detector 25sec.
Maximum distance two detectors center 350m.
After 2×1,5mm (no polarity).
Dimensions: 488x195x85mm.

Look Carbon Monoxide Central
Central detection Carbon monoxide 2 areas. Maximum 16 detectors per zone. installation by 2 wire free architecture and no polarity. 3 programmable levels: ventilation, turbo ventilation and alarm (from 10 in 10 ppm) with independent relay outputs. Delay time of the beginning of programmed ventilation. Time between readings of a detector 25sec. Maximum distance two detectors 350m. After 2×1,5mm (no polarity). Dimensions: 95x195x85mm.

Look Carbon Monoxide Central
Central detection Carbon Monoxide 1 Zone. Maximum 16 detectors. installation by 2 wire free architecture and no polarity. 3 programmable levels: ventilation, turbo and alarm (10 in 10 ppm) with independent relay outputs. Delay time of the beginning of programmed ventilation. Time between readings of a detector 25sec. Maximum distance two detectors center 350m. After 2×1,5mm (no polarity). dimensions 195x195x85mm.

Detector CO Sensitron
Carbon Monoxide Detector (CO), 0-300ppm, 4-20but. Smart 3NC for Car Park.

Look dioxide detector nitrogênio
Nitrogênio dioxide detector probe análise by Electrochemistry High Base. measure of time: <30themselves.
Operating temperature: -10At 50 ° C. Alimentaçăo: 10 a 15 Vdc. Consumption: 5 a 5mA. useful life: 2 years.

Central Gas Detection Sensitron
Gas detection Center 4 Expandable zones 8 (Necessita do módulo ST.PL4/ESP); 12V; IP65.

Nitrogen Detector
nitrogen detector, able to measure the concentration of CO and transmit the reading to the center. (Does not include base).

Look Carbon Monoxide Central
Central detection Carbon monoxide 4 areas. Maximum 16 detectors per zone. installation by 2 wire free architecture and no polarity. 3 programmable levels: ventilation, turbo ventilation and alarm (from 10 in 10 ppm) with independent relay outputs. Delay time of the beginning of programmed ventilation. Time between readings of a detector 25sec. Maximum distance of the detectors to the central 350m. After 2×1,5mm (no polarity). dimensions 488x195x85mm.