The FS4000 fire control panel is designed to operate with conventional automatic fire detectors and manual call points. The panel has outputs provided for external executive devices.
Product description
The FS4000 fire control panel is designed to operate with conventional automatic fire detectors and manual call points. The panel has outputs provided for external executive devices.
The unit is manufactured in four versions:
- 2 Alarm lines of fire – FS4000 / 2
- 4 Alarm lines of fire – FS4000 / 4
- 6 Alarm lines of fire – FS4000 / 6
- 8 Alarm lines of fire – FS4000 / 8
Technical characteristics
fire alarm lines:
- Maximum number of fire detectors in a row: 32
- connecting line: two wires
- Maximum resistance of a line: 100 Oh
Current thresholds for:
- fault condition: 0 – 6 but
- Mode service: 6 – 16 but
- Fire Condition: 16 – 80 but
- Short circuit:> 80 but
Monitored outputs for fire condition:
- Number: 2 parts
- Kind: potential, relay with independent control
- Electrical Characteristics: (19-27,5) V DC / 1A
Relay outputs for fire condition:
- Number: 2 parts
- Kind: potential free, 1 commutation, 1 NA
- Electrical Characteristics: 3A / 125V AC, 3A / 30V DC
relay output for fault condition:
- Number: 1 pcs
- Kind: potential free, commutation
- Electrical Characteristics: 3A / 125V AC, 3A / 30V DC
relay output for fault condition:
- Number: 1 pcs
- Kind: type unmonitored enabled shorted (from a potential free contact)
- Electrical Characteristics: 5 VCC in the normal open state / 0 VDC in activation mode
acting:
- Control over fire alarm lines and controllable outputs for fault conditions (short circuit and interruption) and automatic restart.
- Detection fire detector removed and automatic restart.
- Identification of hand service points.
- LED indication for alarm state and emergency.
- Delay on outputs for fire condition with period 1, 2, 3, 4, 5, 6 or 7 minutes after the registration of Fire condition.
- Option for ‘LOGIC AND’ two fire alarm lines.
- Condition of service in order to direct activation of the 2nd stage of fire condition "for two lines of fire alarm.
- Device Status indication RS485 data transmission.
- Option to turn on / off communication interface RS485.
- Siren built-in fire – a continuous tone, It can be switched off.
- Siren incorporated by fault condition – a tone, discontinuous, It can be switched off.
- Test mode for fire alarm lines.
- Disabling fire alarm lines.
- Disable outputs for fire condition.
- Expand the options through additional relay outputs for fire condition for each line and integrated RS485 for operation on a local network.
- Input for remote reset triggers operation;
Events indications registered:
- Light indication: LED
- As: incorporated ringer
Power supply:
- Tension: (100-240) VAC
- Frequency: 50/60 Hz
Backup batteries:
- Battery Type: lead, gel electrolyte
- Number of Batteries: 2 parts
- rated voltage of the backup battery: 12V
- Nominal capacity C20: (7,0) Ah
- load voltage: 28V DC
Operation in service mode after stopping the main power supply:
lines – 24V / 1,2Ah – 24V / 4,5Ah – 24V / 7,0Ah
2 lines – 32 h – 120 h – 180 h
4 lines – 24 h – 98 h – 140 h
6 lines – 20 h – 80 h – 110 h
8 lines – 16 h – 68 h – 90 h
Consumption in providing backup batteries:
- configuration 2 lines: <35 mA a 24V DC
- configuration 4 lines: <45 mA a 24V DC
- configuration 6 lines: <55 mA a 24V DC
- configuration 8 lines: <65 mA a 24V DC
Power supply to external devices:
- Tension: (19-27) V DC
- maximum current value (including control current outputs): 1,2A
fuses:
- Main power 230V: 4,0 A
- backup battery: 6.0 A
- Power supply to external devices: 1,85 A automatic
- outputs monitored: 1.1 A automatic
Dimension:
- 304mm x 222mm x 94mm
- Weight (spare batteries not included): 0,98 kg